Type:special thermocouple(thermal resistance)

Illustrate:We design special structure for different occasion to directly measure the temperature of liquid, vapor, gas or solid surface ranging from -200C~1600C

Special Thermocouple(Thermal Resistance)

 

Application
 

We design special structure for different occasion to directly measure the temperature of liquid, vapor, gas or solid surface ranging from -200C~1600C

Operation theory
Thermocouple electrode are made of two different materials. Temperature difference between measuring end and reference end results in pyroelectric potential, then display meter indicates the corresponding temperature to the pyroelectric potential.
It is based on that material temperature change of its resistance. When resistance value changes, the working instrument will display relevant temperature.

Main technical parameters
Executive standard
IEC584
IEC751
JB/T5582-1991

Nominal pressure
It generally refers to sustainable static pressure on protection tube from outside without breakage. It concerns not only material, diameter, wall thickness of protection tube, but structure and mounting way of the tube, flow speed and category of tested media as well.
Insulation resistance at normal temperature
The insulation resistance between electrode and protection tube of the thermocouple shall be no less than 1000MW. m under condition that environment temperature is 20±15C, relative humidity is no more than 80%, and test voltage is D.C.500±50V.
The insulation resistance between electrode and protection tube of thermal resistance shall be less than 100MΩ under condition that environment temperature is 15±35C, relative humidity is no more than 80%, and testing voltage is D.C.10~100V.

Thermocouple

 
Type
 
Graduation
Tolerance class
Tolerance value Measuring range ℃ Tolerance value Measuring range ℃
WRN K ± 1.5C -40~+375 ± 2.5C -40~+333
± 0.004|T| 375~-1000 ± 0.0075|T| 333~1200
WRE E ± 1.5C -40~+375 ± 2.5C -40~+333
± 0.004|T| 375~800 ± 0.0075|T| 333~900
WRP S ± 1C 0~+1100 ± 2.5C 0~600
± [1+0.003(t-1100)] 1100~1600 ± 0.004|T| 600~1600
WRQ R ± 1C 0~+1100 ± 2.5C 0~+1100
± [1+0.003(t-1100)] 1100-1600 ± 0.0025|T| 1100~1600
WRR B --- --- --- ---
--- --- ± 0.00425T| 600~1700
 Thermal resistance
Type Graduation Temperature range Accuracy class Tolerance
WZP Pt100 -200~+500 A ±(0.15+0.002)|t|
B ±(0.30+0.005)|t|
WZC Cu50  Cu100 -50~+100 -- ±(0.30+0.005)|t|